Setup - Graco FUSION 309550U Instructions-Parts List Manual

Plural component, impingement mix air purge spray gun series a
Table of Contents

Advertisement

Setup

Setup
1.
Close fluid valves A and B.
2.
Connect A (ISO) and B (RESIN) fluid hoses to fluid
manifold.
3.
Engage piston safety lock, page 10.
4.
Connect gun air whip hose (V) and air valve (W*)
to main air hose. Attach fluid manifold (M) to gun.
M
12
TI2411A
B (RESIN)
TI2417A
A (ISO)
TI2409A
V
W*
TI2554A
To change position of fluid manifold or use
optional fluid inlets, see pages 16 and 17.
5.
Connect quick coupler (D). Turn on air. Open air
valve (W*). Air should flow from nozzle (N).
N
To use optional air inlet, see page 17.
6.
Disengage piston safety lock, page 10.
7.
Trigger gun to check for full mix chamber travel.
Front of air cap (C) should be approximately flush
with front retaining ring (U).
U
C
* (W) Not included with spatter gun.
W*
D
TI2414-1A
TI2410A
TI2414-1A
309550U