Mantel Installation - Dimplex DF203A Owner's Manual

Hide thumbs Also See for DF203A:
Table of Contents

Advertisement

Fireplace Installation
when the heater is operating. Ad-
ditional appliances on the same
circuit may exceed the current
rating of the circuit breaker.
Make sure the units 3-Position
switch is switched OFF (refer to
operating instruction section).
Plug the unit into a 15 Amp/120
VAC outlet.

Mantel Installation

For use with a new or existing
mantel, insert fireplace as shown
in Figure 7 and anchor in place
with supplied screws.
If not installing the unit into a Dim-
plex mantel the required open-
ing dimensions of the fireplace
are: 20.4" (517mm) wide x 21.1"
(536mm) high.
(See Figure 8 for all dimensions)
WIRING
L1
N
10
N
L
CUTOUT
Figure 8
21.1 [537]
22.1 [561]
BLOWER
MOTOR
M
ELEMENT
THERMOSTAT
21.9 [555]
20.4 [517]
9 [229]
21.1 [536]
LIGHT HARNESS
ASSEMBLY
M
www.dimplex.com
FLICKER
MOTOR

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents