Hvlp Operation; Fluid Application - Graco 288844 Instructions Manual

Aa series spray gun
Hide thumbs Also See for 288844:
Table of Contents

Advertisement

Operation

HVLP Operation

For HVLP operation, the atomization air must not
exceed 10 psi. Use HVLP Verification Kit 249140 to
verify air psi.
There is no fan adjustment when using RAC tips
and caps.

Fluid Application

Always hold the gun at a right angle from the surface.
Do not make an arc with the gun as it causes an uneven
coat of fluid. See F
. 16.
IG
INCORRECT
F
. 16
IG
12
1. To achieve the best results when applying fluid,
keep the gun perpendicular to the surface and main-
tain a consistent distance of approximately 8 to 12
in. (200 to 300 mm) from the object being sprayed.
2. To obtain an even finish, use smooth, even strokes
across the object being sprayed with 50% overlap.
3. Paint using parallel strokes. This spray gun applies
all coatings evenly without cross coating.