Cable pair termination
Cable Length
Anomalous coupling between cable pairs can be caused by shorted wires, improper termination, or high crosstalk resulting
from an incorrect wire map. These conditions can all prevent the PLANET Switch from establishing a link. The screen in
Figure 4-85
appears.
The Cable Diagnostics includes the following fields: Table 4-37 Description of the Cable Diagnostics.
Item
Description
Port
Specifies the port numbers for which to run the cable diagnostics.
Mode
There're three cable test mode for selection:
Full – test full pairs
Anomaly – test with only anomaly pairs
Anomaly w/o X-pair - test anomaly pairs but without X-pair
Button
Apply
Press this button for start the cable diagnostics process.
Figure 4-85 Cable Diagnostics
Table 4-37 Description of the Cable Diagnostics
-116-