Maytag Dryer Service Manual page 69

Hide thumbs Also See for Dryer:
Table of Contents

Advertisement

MDE/MDG7500, MDE/MDG9800
Diagnostic Codes
Code
Description
1
Dryer Thermistor
Short Sensed
2
Thermistor Open
Sensed
Door Circuit
3
Failure
4
Possible motor
transistor error
5
Not Used
6
Non Volatile
Memory
16023110
16023110
cycle count
xxxx
exit diagnostic/
clear
help codes
help codes
Trigger
Action Taken
The
Check for:
thermistor
-
Clogged lint
resistance is
screen.
very low,
-
Restricted
with a
vent system.
temperature
Failed thermistor.
> 175
degrees.
The
Check for:
thermistor
- Low ambient
resistance is
temperature in
very high
room (Below
50oF/10oC).
- Outside vent
damper is stuck
open in
wintertime.
Loose or open wire
terminals
Invalid state
Check for:
for more
- Loose or open wire
than 256
terminals in Door
milliseconds
Sense circuit.
If either
Check for:
motor
- Loose
transistor is
connections in
seen open or
motor circuit.
shorted
- Run System
during
Check Mode
startup
and check the
motor relay
function.
- If relay
functions,
disregard the
diagnostic
code.
If relay does not
function, replace
machine control
board.
Problem
Disregard
Detected
with integrity
of
parameters
stored in
EEPROM
memory.
© 2000 Maytag Appliances Sales Company
Code
Description
Trigger
8
Stuck Key
A key is
sensed to be
pressed
more than
75 seconds,
the key shall
be assumed
to be stuck.
Membrane Pad Continuity Checks
Note: Unplug connector and touch probe of meter to the
appropriate pin numbers. Meter will show infinity on
open keys and continuity on closed keys.
Membrane
Pin Number
Pad
Home
J7(3)
Favorites
J7(4)
Back
J7(3)
Start/Pause
J7(4)
Off
J7(3)
Help
J7(4)
Section 9.
Dryer Controls Overview
Action Taken
Run membrane pad
check and replace
console w/membrane
pad if necessary.
Pin Number
J7(5)
J7(5)
J7(6)
J7(7)
J7(7)
J7(6)
9-17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1999 sloped-front

Table of Contents