First Alert FA168C-CN User Manual page 47

Hide thumbs Also See for FA168C-CN:
Table of Contents

Advertisement

SOUND
CAUSE
LOUD,
FIRE ALARM.
INTERRUPTED*
Keypad & Ext.
LOUD,
BURGLARY/AUDIBLE
CONTINUOUS*
EMERGENCY ALARM.
Keypad & Ext.
ONE SHORT BEEP
a. SYSTEM DISARM.
(not repeated)
b. SYSTEM ARMING ATTEMPT
Keypad only
c. BYPASS VERIFY.
ONE SHORT BEEP
a. SYSTEM IS IN TEST MODE.
(once every 40 secs)
b, LOW BATTERY AT A
Keypad only
TWO SHORT BEEPS
ARM AWAY or MAXIMUM.
Keypad only
THREE SHORT
a. ARM STAY, NIGHT-STAY,
BEEPS
OR INSTANT.
Keypad only
b. ZONE OPENED WHILE
RAPID BEEPING
a. TROUBLE.
Keypad only
b. MEMORY OF ALARM.
c. SYSTEM LOW BATTERY.
d. EXT. SOUNDER WIRE FAIL.
SLOW BEEPING
a. EXIT DELAY WARNING
Keypad only
b. ENTRY DELAY WARNING.
* If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady
ring.
6XPPDU\RI$XGLEOH9LVXDO1RWLILFDWLRQV
$OSKD'LVSOD\.H\SDGV
WITH AN OPEN ZONE.
TRANSMITTER.
SYSTEM IS DISARMED.
(if programmed).
DISPLAY
FIRE is displayed; descriptor of zone in alarm is
displayed. If a fire alarm is manually activated, zone
number 95 will be displayed.
ALARM
displayed. If programmed, descriptor of
zone in alarm is also displayed
a. DISARMED/READY TO ARM is displayed.
b. Number and descriptor of open protection zone is
displayed.
c. Numbers and descriptors of the bypassed zones
are displayed (One beep is heard for each
zone displayed). Subsequently, the following is
displayed: DISARMED BYPASS /Ready to Arm.
a. Opened Zone identifications will appear.
b. LO BAT displayed with description of transmitter.
ARMED AWAY or MAXIMUM displayed. Red
ARMED indicator lit.
a. ARMED STAY or ARMED INSTANT displayed.
Red ARMED indicator lit.
b. CHIME displayed, descriptor of open protection
zone will be displayed if the [✱] key is pressed.
a. CHECK displayed. Descriptor of troubled
protection zone is displayed.
b. FIRE or ALARM is displayed; descriptor of zone
in alarm is displayed.
c. SYSTEM LO BAT displayed.
d. BELL FAILURE is displayed.
a. ARMED AWAY OR MAXIMUM is displayed
along with You May Exit Now.
b. DISARM SYSTEM OR ALARM WILL OCCUR
is displayed. Exceeding the delay time without
disarming causes an alarm.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fa148cp-cnFa148cpFa168c

Table of Contents