The keypad beep to acknowledge your input and
displays the command you entered (followed by "F").
4. Enter the next command, followed by press/holding
the "D" key for at least two seconds. The keypad
beeps and displays the keystrokes entered so far.
5. Repeat until the all the desired commands (up to 16
characters including the "F"s) have been entered.
Be sure to check your keystrokes before continuing.
If you made a mistake, you must start over.
6. To exit, press/hold the "D" key for at least two
seconds. The display returns to system status and
indicates system is ready.
Suppose you want to (1) bypass the two upstairs window zones, then (2) turn on an
exterior light, and then (3) arm the security system in the AWAY mode. The
procedures in the table that follows show you how you would program this macro:
1. Bypass zones 02 & 03
2. Insert terminator.
3. Turn light on
(device 01).
4. Insert terminator.
5. Arm system AWAY
6. Insert terminator.
System must be disarmed before performing a macro function.
Press
key, then
2-digit zone numbers 02 & 03.
Press the "D" key for at least 2 seconds.
Press [#] and 7 keys for "device ON", and
[01] key for selecting device 1.
Press the "D" key for at least 2 seconds.
Press
key.
Press the "D" key for at least 2 seconds.
Press the Macro key programmed for the desired
series of commands for at least 2 seconds. The "Enter
User Code" prompt appears. The prompt remains
displayed for up to 10 seconds.
Enter your 4-digit user code.
The programmed macro sequence begins
automatically after the user code is entered.
     *    *  *
    
     *
     *   
     *    *
     *    * 
     *    *  *