Installation and electrical connection

Please refer to the type plate for specifications about
the power supply. The nominal voltage stated on the
type plate and type of current must be identical with

Information for the electrician

When connecting the appliance without a plug, care
must be taken that this is done correctly. Please fol-
low the relevant information in the section on install-
ing and connecting the appliance.
For appliances with variable voltage settings, the
switch-over diagram can be found on the cover of the
connection box at the back of the appliance.

Special accessories

You can obtain the following special accessories from
your retailer.

Drainage kit

With this kit (E-No. 916 019 000) you can lead the
condensate directly into a drain (sink, siphon, drain
grating) with a maximum feed height of 1m above the
floor on which the dryer is standing (3m Length).
Emptying he condensate container is then no longer
necessary.
You can then suppress the EMPTY WATER
(BEHÄLTER) indicator at the end of each program
with the aid of the appliance programming features
(see " Programming possibilities" section). However,
85x60x60cm
(5 kg Cotton, spun at 800 revolutions per minute,
program COTTON CUPBOARD DRY - BAUMWOLLE
117cm
SCHRANKTROCKEN)
1.0/–0.4cm
Area of use
approx. 46 kg
Permissible ambient temperature +5°C up to +35°C
max. 5kg
;
3.5
the nominal voltage and type of current at the point of
installation. Also refer to the type plate for the fuse
required.
If the appliance is connected by a plug to 230 V AC,
only a Type 12 L+N+PE 250 V, 10 A Swiss plug may
be used in accordance with Standard Specifications
Sheet SEV 6534-2,1991. The plug must be installed
in phase in accordance with the rating plate (it is
essential that phase L of the socket is contacted with
the brown wire of the mains cable).
Improper connection can lead to the risk of a fire in
the dryer.
the condensate container must be inserted correctly
in the operator control mask.
This appliance complies with the following
EC directives:
– 73/23/EEC of 19/2/1973 'Low voltage
directive'
– 89/336/EEC of 3/5/1989 'EMC directive'
including the
Modification directive 92/31/EEC