Electrical Connection - Electrolux EKG 600102 Instruction Booklet

Electrolux gas cooker
Table of Contents

Advertisement

Available languages

Available languages

Electrical connection

The unit is preset to work with a
voltage of single phase 230 V.
Before making the connection make
sure that:
- the energy power available in the
user's house is sufficient for the
normal supply of this appliance (see
rating plate).
- the unit is correctly connected to earth
through a suitable plug and according
to the installation country Laws.
- the socket or the omnipolar switch
used for the connection must be
easilv reached with the installed
appliance.
The appliance is supplied with
electric cable, therefore you will have to
fit it with a standard plug, suitable for the
total electric load shown on the rating
plate. The plug is to be inserted into a
suitable wall socket.
If you wish to directly connect to the
mains, you have to interpose an
omnipolar switch with a minimum
opening between contacts of 3 mm,
between the unit and the mains,
complying with the existing regulations.
The brown live wire (originating from the
clamp of the appliance junction box)
must always be connected to the phase
of the mains supply. In any case, the
supply cord must be positioned in such
a way as it doesn't reach in any point a
temperature higher by 50°C than the
room temperature.
Replacement of the electric
cable
The replacement of electric
cable must be carried out
exclusively by the service
force centre or by personnel
with similar competencies, in
accordance with the current
regulations.
Should the supply cord need to be
replaced, use only the following cable
types: H07 RN-F, H05 RN-F, H05 RR-
F, H05 VV-F, H05 V2V2-F (T90), H05
BB-F. It is necessary that the yellow/
green earth wire is about 2 cm longer
than the live and neutral ones (see
diagram). After the connection, test the
heating elements for about 3 minutes to
ensure that they are working correctly.
The manufacturer refuses any
responsability in cases where
normal safety measures are not
observed.
Phase
Ground (yellow - green)
electrolux 33
Neutral
wire