Electrolux EKG 600102 Instruction Booklet page 26

Electrolux gas cooker
Table of Contents

Advertisement

Available languages

Available languages

26 electrolux
Hob
Rear left burner (semi-rapid)
2000 W (G20 20 mbar/G30 30 mbar)-
1400 W (G20 13 mbar)
Front left burner (rapid)
3000 W (G20 20 mbar)-2800 W (G30)-
1900 W (G20 13 mbar)
Rear right burner (semi-rapid)
2000 W (G20 20 mbar/G30 30 mbar)-
1400 W (G20 13 mbar)
Front right burner (auxiliary)
1000 W (G20 20 mbar/G30 30 mbar)-
900 W (G20 13 mbar)
Dimensions of the appliance
Height
Depth
Width
Oven Capacity
Appliance Class 1 and Class 2 Sub-Class 1
Category:
Appliance set for use with gas type:
G20 20 mbar
Burner characteristics
BURNER
TYPE
OF GAS
POSITION
NOMINAL THERMAL
NATURAL
POWER (kW)
NOMINAL FLOW
GAS
RATE (m
20 mbar
NOZZLE REFERENCE
NOMINAL THERMAL
POWER (kW)
LPG GAS
NOMINAL FLOW
30 mbar
RATE (g/h)
NOZZLE REFERENCE
1/100 mm
NOMINAL THERMAL
NATURAL
POWER (kW)
GAS
NOMINAL FLOW
*
RATE (g/h)
13 mbar
NOZZLE REFERENCE
1/100 mm
* Natural gas G20 13 mbar to be used only in Russia
850 mm
600 mm
600 mm
II2H3B/P
MAX
3.0
3
/h)
0.286
119
2.8
202
86
1.9
0.181
120
By-pass diameters
Burner
56 l
Auxiliary
Semi-rapid
Rapid
Oven
RAPID
SEMI-RAPID
(large)
(medium)
MIN
MAX
0.65
2.0
0.062
0.190 0.043 0.095 0.031 0.257 0.095
Adjust.
96
Adjust.
0.65
2.0
47
144
40
71
0.65
1.4
0.062
0.133 0.043 0.086 0.031 0.229 0.095
Adjust.
105 Adjust.
Ø By-pass in 1/100 of mm.
28
32
40
52
AUXILIARY
(small)
MIN
MAX
MIN
0.45
1.0
0.33
70
Adjust.
0.45
1.0
0.33
33
72
24
32
50
28
0.45
0.9
0.33
80
Adjust.
OVEN
MAX
MIN
2.7
1.0
114 Adjust.
2.7
1.0
196
73
83
52
2.4
1.0
123 Adjust.
X