Measures to prevent wrong electrical connection

If a range with pyrolytic self-cleaning system is connected wrongly, the micro processor at the Pris-
ma basic power board recognises this error. It changes over into the fault mode. The error is
reported by the error code display F7 in the display of the oven respectively E7 in the display of the
hot plates.The heaters are dead. The connection error can be corrected. Then the range can be
operated quite normally.
Fig. Versions of connection
6.4

Thermal link

A thermal link is provided in all appliances at the left side at the air duct, which switches off the
device in case of overheating.
Fig. Thermal link (Klixon)