Instructions For The Installer; Electrical Connection - AEG B 99697-5 Operating Instructions Manual

Aeg built-in oven
Table of Contents

Advertisement

48

Instructions for the Installer

The instructions given below are
designed specifically for a qualified
installer and should aid him or her to
perform all installation, adjustment,
and maintenance operations with
absolute precision and in compliance
with all current legislation and
regulations. We strongly recommend
that all operations for the installation
of your cooker be carryed out by
Qualified Personnel in accordance with
existing rules and regulations.

Electrical connection

Prior to making the electrical connection, make
sure that:
— the protection fuse and the domestic
wiring system are suitable to carry the total
electric load of the oven (see rating plate);
— your domestic wiring system has an
efficient earth connection in compliance with
rules and laws in force;
— the wall socket or the omnipole switch
used for the electrical connection can easily
be reached after the oven is built in.
Electrical Requirements
Any permanent electrical installation must
comply with the latest I.E.E. Regulations and
local Electricity Board regulations. For your
own safety this should be undertaken by a
qualified electrician, e.g. your local Electricity
Board, or a contractor who is on the roll of the
National Inspection Council for Electrical
Installation Contracting (NICEIC).
The oven is designed to be connected to 230
V (50 Hz) electricity supply.
The oven has an easily accessible terminal
block which is marked as follows:
Letter L
-
Letter N
-
or E
-
THIS OVEN MUST BE EARTHED
The cable used to connect the oven to the
electrical supply must comply to the
specifications given below.
For Uk use only
Connection
Min. size
via
Cable/flex /flex
• 13 A socket 2.5 mm
outlet
• 13 A
spur box
• Oven
2.5 mm
Control
Circuit
For Europe use only
Min. size
Cable / flex type
Cable/flex
2
1.5 mm
H07 RN-F, H05 RN-F, 13 A
H05 RR-F, H05 VV-F,
H05 V2V2-F (T90),
H05 BB-F
Live terminal
Neutral terminal
Earth terminal
Cable
Fuse
type
2
3 core
13 A min.
butyl
insulated
2
PVC/PVC
15 A min.
twin and
20 A max.
earth
Fuse