USER MANUAL
IMPORTANT SAFETY INSTRUCTIONS
WARNING: Opening or removing the cover may expose you to lethal voltages within this unit even
when it is apparently not operating and the input wiring is disconnected from electrical source.
Observe all cautions and warnings in this manual. Failure to do so MAY result in serious injury or
death. Refer all UPS and battery service to qualified service personnel. Do not attempt to service this
product yourself. Never work alone.
1.
SAVE THESE INSTRUCTIONS. THIS MANUAL CONTAINS IMPORTANT SAFETY INSTRUCTIONS. Read all safety
and operating instructions before operating the Uninterruptible Power System (UPS). Adhere to all warnings on the unit
and in this manual. Follow all operating and user instructions. This equipment can be operated by individuals without
previous training.
2.
This product is designed for Commercial/Industrial use only. It is not intended for use with life support and other
designated "critical" devices. Maximum load must not exceed that shown on the UPS rating label. The UPS is
designed for data processing equipment. If uncertain, consult your dealer. See Limited Warranty.
3.
This UPS is designed for use on a properly earthed (grounded), 208-240 VAC, 50Hz or 60Hz supply, for installation by
qualified personnel. A qualified electrician must review and approve customer supplied wiring, circuit breakers,
intended loads, and verify correct input, output and earth connections to ensure compliance with technical standards
and local electrical codes of practice. Installation instructions and warning notices only for use by qualified personnel
are located after the UPS operator instructions in this manual.
4.
ELECTROMAGNETIC COMPATIBILITY- The GXT3x1 6 & 8 & 10 kVA , complies with the limits for a Class A digital
device, pursuant to EN50091-2 rules. These limits provide reasonable protection against harmful interference in a
commercial environment. This device generates, uses, and radiates radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio communications. Operating
this device in a residential area is likely to cause harmful interference, which the user must correct at his own expense.
5.
Operate the UPS in an indoor environment only in an ambient temperature range of 0°C to +40°C (32°F to +104°F).
Install it in a clean environment, free from moisture, flammable liquids, gasses, or corrosive substances.
6.
This UPS contains no user serviceable parts. The UPS ON/OFF pushbuttons do not electrically isolate internal parts.
Under no circumstances attempt to gain access internally, due to the risk of electric shock or burn.
Do not continue to use the UPS if the front panel indications are not in accordance with these operating instructions, or
the UPS performance alters in use. Refer all faults to your dealer.
7.
Only trained engineers authorized by Liebert should perform troubleshooting. To replace batteries, refer all servicing
to qualified service personnel. PROPER DISPOSAL OF BATTERIES IS REQUIRED. REFER TO YOUR LOCAL
LAWS AND REGULATIONS FOR DISPOSAL REQUIREMENTS.
8.
Never block or insert any object into the ventilation holes or other openings.
9.
DO NOT CONNECT equipment that could overload the UPS or demand DC current from the UPS, for example: electric
drills, vacuum cleaners, laser printers, hairdryers or any appliance using half wave rectification.
10.
Storing magnetic media on top of the UPS may result in data loss or corruption.
11.
Turn the UPS off and isolate the UPS before cleaning. Use only a soft cloth, never liquid or aerosol cleaners. Keep the
front and rear vents free of dust accumulation that could restrict airflow.
IMPORTANT SAFETY INSTRUCTIONS
(06/02)
UPStation GXT 3x1
Page v