Connection Module - Axis 231D User Manual

Network dome camera
Hide thumbs Also See for 231D:
Table of Contents

Advertisement

Connection Module

This section describes the pinout provided by the Connection module consisting of:
• 4 transistor outputs
• 4 digital inputs
• power and GND (ground)
The inputs/outputs are used in applications for, e.g. event triggering, time lapse recording,
alarm notification via email, picture storage to FTP locations.
• Input - e.g. a doorbell. If the doorbell is pressed, the state changes, and the input
will be active (shown under Event Configuration | Port Status).
• Output - e.g. an alarm device that can be activated from Output buttons from the
Live View page or as an action to an Event Type. The output will show as active
(under Event Configuration | Port Status), if the alarm device is activated.
Connection Module Pinout
Function
Description
n/a
not used
n/a
not used
n/a
not used
n/a
not used
n/a
not used
n/a
not used
n/a
not used
PS GND
ground
24 VAC
24 VAC
24 VAC
24 VAC
1. Loosen the corresponding screw on top of the pin (see the table above to determine
which pin to use).
2. Push the cable into the connector and secure it by fastening the screw.
AXIS 231D - Connection Module
not
used
24V AC Power
Function
Description
GND
ground
GND
ground
Transistor Output 4
Digital Input 4
Connect to GND to activate or leave floating
(unconnected) to deactivate
Transistor Output 3
Digital Input 3
Transistor Output 2
Max. load 100mA, max. voltage 24VAC.
An open-collector NPN transistor with the
Transistor Output 1
emitter connected to pin 2 (GND). If used
Digital Input 2
with an external relay, a diode must be
Digital Input 1
connected in parallel with the load for
protection against any voltage transients.
4 transistor outputs
4 digital inputs
(see table below)
41