Installation - Xantrex Digital echo-charge Owner's Manual

12/24 volt -15a
Table of Contents

Advertisement

Prevent unnecessary damage by carefully following
Battery Connections
Two feet of 16 gauge wire with a ring terminal on the end is connected
to the Digital echo-charge unit. Connect the ring terminals to the batteries
as indicated.
Connect from the echo-charge:
Ground wire (black) to the negative battery ground.
Starter Battery wire (red with yellow trace) to the starter battery
positive (+ red) terminal. A 20 amp fuse in this line protects the wire.
House Battery wire (+ red) to the house battery bank positive (+ red)
terminal. A 20 amp fuse in this line protects the wire.
Use 12 gauge wire to extend wire if needed. Avoid using long connec-
tion wires. The longer the wires, the less current will flow and the longer it
will take to charge the starter battery.
After all connections have been made, turn the charger ON. The Digital
echo-charge will follow the charger and begin to charge the starter
battery.
Note: When the House Battery and Ground connections have been
made, the Digital echo-charge's LED will light Green. When the starter
battery connection is made, charging will begin.
WARNING
Make sure all charging sources are switched
OFF and no charging voltage is present
before beginning installation.
the installation instructions.

INSTALLATION

7