LOCAL ON, LOCAL OFF (F7)
The Local On setting (the default status of the
instrument) corresponds to the situation when the
keyboard is connected to the internal sound en-
gine.
Press F7 to set the instrument for Local Off op-
eration (shown in negative highlight). Local Off
operation disconnects the SK760/880 keyboard
from the internal sound generator. The keyboard
sends data from the Group A MIDI OUT on chan-
nel 1. In Local Off mode, the internal sound en-
gine responds only to data received at MIDI IN.
The keyboard cannot play the internal SK760/
880 sounds directly.
Activate Local Off to program Songs on an ex-
ternal sequencer. SK760/880 transmits data to
the external sequencer, and the sequencer re-
turns the data to the SK760/880 internal sound
engine.
MIDI OUT
MIDI IN
MIDI LOCK (F8)
When this function is selected (shown in nega-
tive highlight), the current MIDI channel configu-
ration and filters of the tracks is locked for all
Performances. The individual situations of Per-
formances are overridden.
When the option is not selected, the tracks are
reset to the settings of the current Performance.
The MIDI Lock setting is conserved in memory
after power down. It is saved to the Setup.