Function Codes - Common Settings - LG ARNH963K2A2 Installation Manual

Hydro kit medium temperature (k2) btu/h 107,500; hydro kit high temperature (k3) btu/h 86,000
Hide thumbs Also See for ARNH963K2A2:
Table of Contents

Advertisement

Pre-coMMIssIoNING

Function Codes - Common Settings

Table 14: Installer Setting - Function Codes and Parameters (Continued)
function
DHW Tank Temperature Setpoint
Freeze Protection Setpoint
DHW Water Heating Timers
Change Thermal ON/OFF
Air Temperature.
Change Thermal ON/OFF
Leaving Water Temperature
Program Version
* Deadpan is the difference between the upper and lower limit setpoints and the temperature value is in Fahrenheit.
Customer is responsible for maintaining the quality of water in the water circuit.
function code Descriptions and common settings
Table 15 gives a brief description of each Function Code for both Hydro Kit models. Refer to this table, along with Table 14 when customizing
the settings through the Installer.
Table 15: Common Function Code Descriptions for Hydro Kits K2 and K3
function Code
Common Settings
02 - Disable 3 Minute Delay
03 - Remote Air Sensor Connection
04 - Celsius/Fahrenheit Switching
05 - Setting Temperature Selection
06 - Auto Dry Contact
07 - Address Setting
08 - Override Setting
60
default
Value #1
28:005:080
33 ~ 68
: Temp. gap from Value #2
29:003:000
35 ~ 39
2b:030
5 ~ 95 min (step: 5 min)
2b:180:020
0 ~ 600 min (step: 30 min)
2E:00
2F:00
30:***
Display Version Number
This function is only used for an inspection in a factory.
Remote Air Sensor is connected to the unit and controls by room air
temperature.
Temperature can be switched to read Celsius or Fahrenheit.
Unit can be operated either by air temperature or water temperature.
Air temperature can only be enabled in conjunction with Remote Air
Sensor Connection if enabled and Function Code 03 is set as 02.
Allows the Dry Contact to operate under Auto Run Mode or Manual
Mode with Remote Controller. If thermostat is used, value should be
changed from "2" to "1".
If Central Controller is installed, address assigning can be set through
this function.
Overrides Master/Slave selection functionality to prevent the unit's
various mode operation.
Example: If the unit is set as the Slave, it blocks the ability to switch
the unit to the opposite operating mode (such as cooling/heating).
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp.
122 ~ 176
20 ~ 95 min (step: 5 min)
00~03
00~03
description
Value #2
Actual Low/Actual High
Comments
00~01
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Arnh763k3b2

Table of Contents