Replacing The I/O Module; Table 7-6 I/O Module Replacement Procedure - Compaq 4200 User Manual

Lvd disk enclosure
Hide thumbs Also See for 4200:
Table of Contents

Advertisement

7–12
Compaq StorageWorks Enclosure 4200 Family LVD Disk Enclosure User Guide

Replacing the I/O Module

NOTE: Removing an I/O module significantly changes the airflow within the enclosure.
Therefore, always replace it as soon as possible.
The basic procedure for replacing an I/O module is the same regardless type. Complete the
procedure in Table 7–3 to replace an I/O module.
1.
After backing up the stored data, stop all data transfers.
2.
Stop all transfers on the SCSI bus.
3.
Disconnect the SCSI bus cable from the module connector
For a dual-bus I/O module, label the cables as remove them.
4.
While grasping the module handle, press down on the module latch
the enclosure.
1
CAUTION: Interrupting the SCSI bus by replacing an I/O module could cause the loss
of data. Therefore, you must stop all SCSI bus data transfers before replacing a
module.
You must stop transfers on both SCSI buses when the enclosure is configured for dual
bus operation.
Table 7–6 I/O Module Replacement Procedure
2
3
CXO7062A
.
and pull the module out of

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks 4200 series

Table of Contents