COMPONENT
High-Voltage Capacitor
CAPACITOR
Blower Motor Capacitor
High-Voltage Rectifier
RECTIFIER
DIODE
ANODE
TEST PROCEDURE
Terminal-To-Terminal
Set the ohmmeter to the R x 10 k
scale, and measure the resistance
across the capacitor terminals.
Terminal-To-Case
Set the ohmmeter to the R x 1
scale, and measure the resistance
between each terminal and the
case.
Terminal-To-Terminal
Set the ohmmeter to the R x 10 k
scale, and measure the resistance
across the capacitor terminals.
Forward Continuity
Set the ohmmeter to the R x 1
scale, and measure the forward
resistance across the rectifier ter-
minals with the (+) lead touching
the anode and the (–) lead touch-
ing the cathode.
CATHODE
Reverse Continuity
Set the ohmmeter to its highest
scale, and measure the reverse
resistance across the rectifier ter-
minals with the (+) lead touching
the cathode and the (–) lead touch-
ing the anode.
RESULT
3-20
a) Normal - The meter indi-
cates several ohms, then
gradually returns to in-
finity.
b) Abnormal - The meter
indicates infinity, or zero
ohms (a short) immedi-
ately.
a) Normal - The meter indi-
cates infinity.
b) Abnormal - The meter
indicates zero ohms, or
a short.
a) Normal - The meter indi-
cates several ohms, then
gradually returns to in-
finity.
b) Abnormal - The meter
indicates infinity, or zero
ohms (a short) immedi-
ately.
a) Normal - The meter indi-
cates several ohms.
b) Abnormal - The meter
indicates infinity, or zero
ohms (a short).
a) Normal - The meter indi-
cates infinity.
b) Abnormal - The meter
indicates infinity, or zero
ohms (a short).