Download Print this page

Removing The Gas Sensor - KitchenAid KHMS105E Service Manual

E series
Hide thumbs

Advertisement

WARNING
Personal Injury Hazard
Disconnect from the electrical supply be-
fore servicing the unit. Failure to do so
could result in death or electrical shock.
Discharge the high voltage capacitor be-
fore working inside the oven. Failure to do
so could result in death or electrical shock.
CAUTION: Because of the weight and size of
the microwave oven, two people are required
to safely move and install it. Failure to do so
could result in personal injury.
1.
Disconnect the electrical supply to the
microwave oven.
2.
Remove the microwave oven from its
mounting location (refer to page 2-2 for
the procedure).

REMOVING THE GAS SENSOR

GAS SENSOR
ASSEMBLY
COVER
3.
Remove the vent grille and the cabinet
from the microwave oven (refer to page
2-2 for the procedure).
4.
Unclip the gas sensor cover and remove
it.
5.
Remove the screw from the top center tab
of the control panel (see the illustration
on page 2-17).
6.
From the top and back of the control
panel, lift the top locking tab and pull
the top of the panel out slightly, then lift
the bottom tabs of the panel out of the
slots and pull it forward (see page 2-17).
7.
Unplug 3-wire gas sensor connector CN4
from the control circuit board and remove
the gas sensor from the microwave oven.
8.
Install the new gas sensor and then reas-
semble the microwave oven.
RED
WHT
YEL
2-24
PINS