TOUCH PANEL CONTINUITY TEST
1.
Unplug the microwave oven's power sup-
ply cord.
2.
Open the oven door.
3.
Plug the power cord back into the AC
receptical. You should see the following
display if all of the interlock switches are
open:
888:88
PROGRAMMING CHECKS
If the sensor is defective, or if the wires are not
properly connected, you will see the following
display:
– f 1 –
If any of the switches are closed, you will see
the following display:
– f 2 –
If the temperature probe is not plugged into
the jack, or if the wires are not properly con-
nected, you will see the following display:
– f 4 –
3-10