Troubleshooting - Icom IC-M31 Instruction Manual

Hide thumbs Also See for IC-M31:
Table of Contents

Advertisement

10

TROUBLESHOOTING

PROBLEM
The transceiver does
not turn ON.
No sound from speaker. • Squelch level is too deep.
Transmitting is impossi-
ble, or high power can
not be selected.
The displayed channel
cannot be changed.
Scan does not start.
No beeps.
Self check error.
(Temperature)
Self check error.
(Battery voltage)
Self check error.
(Water intrusion)
27
POSSIBLE CAUSE
• The battery is exhausted.
• Bad connection to the battery pack.
• Volume level is too low.
• Speaker has been exposed to water.
• Some channels are for low power or re-
ceive only.
• The battery is exhausted.
• The battery over charged.
• The output power is set to low.
• Lock function is activated.
• "TAG" channels are not programmed.
• Beep tones are turned OFF.
• The temperature is outside of –25°C to
+65°C (approx)
• The connected battery pack's voltage is
more than 11 V.
• Water has entered the transceiver.
SOLUTION
• Recharge the battery pack.
• Check the connection to the transceiver.
• Set squelch to the threshold point.
• Push [+]/[–] to set a suitable level.
• Drain water from the speaker.
• Change channels.
• Recharge the battery pack.
• Verify the battery voltage is correct.
• Push [H/L•
] to select high power.
LOCK
• Push [H/L•
] for 1 sec. to cancel the
LOCK
function.
• Set the desired channels as "TAG" channels. p. 14
• Set the beep tones to ON (Fix Beep/User
Beep) in SET mode.
• Leave the transceiver at room temperature
for a while. Turn the power ON to check if the
internal temperature has returned to normal.
• Verify the battery voltage is correct.
• Have the transceiver checked at your local
distributor or dealer to see whether the trans-
ceiver works properly or not.
REF.
p. 21
p. 3
p. 9
p. 9
pgs. 7,
8, 28
p. 21
p. 10
p. 12
p. 17

Advertisement