Advertisement

Quick Links

GB-5751010800
26-01-2004
I m p o r t a n t s a f e g u a rd s
• Use this appliance only as described in this instruction manual.
As with any electrical appliance, whilst the instructions aim to cover as many eventualities as
possible caution and common sense should be applied when operating and installing this air
conditioner.
• This appliance has been manufactured to cool and de-humidify domestic environments and
should not be used for other purposes.
• It is dangerous to alter or modify the unit's characteristics in any way.
• The appliance must be installed in line with the relevant national legislation.
• Should repairs be necessary, contact the nearest authorised Repair Service Centre. Unautho-
rised servicing can be dangerous.
• This appliance is to be used by adults only; keep away from children.
• In the case that the power cable becomes damaged, this must be substituted only by specialised
personnel authorised by the manufacturer.
• Always ensure the appliance is earthed. If you have any doubts check with a qualified elec-
trician.
• Avoid using extension leads with the unit.
• Before cleaning or maintenance operations, always unplug the unit from the socket.
• Do not pull on or place strain on the power cable when moving the appliance.
• The appliance should not be installed where the atmosphere may contain combustible gases,
oil or sulphur, or near heat sources.
• If the appliance is utilised in areas where there is no ventilation of air, it is necessary to take pre-
cautions to avoid that the refrigerant gases that may leak from the appliance do not remain
in the room, thereby causing a fire hazard.
• This appliance must be utilised and installed only in rooms with a total volume of 15 cubic metres
or greater.
• The refrigerant used in this appliance would cause damage to the ozone layer if relased into the
atmosphere. Therefore at the end of the working life of the appliance the unit should be taken to
a recycling centre for disposal of the refrigerant.
• Keep the unit at least 50 cm away from inflammable substances (alcohol etc) or pressurised con-
tainers (eg. aerosol cans).
• Do not rest hot or heavy objects onto the appliance.
• Clean the filters at least once a week.
• Remember to perform the descaling procedure at the end of each season (see page 25). In
areas where the water is particularly hard (rich in minerals), the use of a commercial anti-lime
product added to the water is recommended. This can be requested from De'Longhi LTD.
• Avoid using heaters near the unit.
• Do not cover this appliance with bags when is not in use
• Unventilated area where the appilance using flammable refrigerants is installed shall be so con-
structed that any leaked refrigerants will not stagnate so as to cause a fire or an explosion hazard
caussed by igniting stagnant refrigerants from other source such as electric heater, stove and simi-
lar home applications.
• The unit should be transported in a vertical position. If this is not possible secure the unit at an
angle, do not lie horizontally.
Before transporting the unit drain the condensation collecting-tray and tank. After transporta-
tion, wait at least 1 hour before switching on the unit.
• The packaging materials can be recycled. You are therefore recommended to place them in
the special containers for differentiated waste collection.
16
16:26
Pagina 16

Advertisement

Table of Contents
loading

Summary of Contents for DeLonghi PAC 46ECO

  • Page 1 GB-5751010800 26-01-2004 16:26 Pagina 16 I m p o r t a n t s a f e g u a rd s • Use this appliance only as described in this instruction manual. As with any electrical appliance, whilst the instructions aim to cover as many eventualities as possible caution and common sense should be applied when operating and installing this air conditioner.
  • Page 2 GB-5751010800 26-01-2004 16:27 Pagina 17 How does your Pinguino work uring the summer, optimum comfort is achieved with a temperature of between 24 and 27˚C and about 50% relative humidity. An air conditioner removes moisture and heat from the room where it is located. One advantage of portable air conditioning units over fitted models is that they can be moved from one room to another in the home or even transferred between different buildings.
  • Page 3 GB-5751010800 26-01-2004 16:27 Pagina 18 S e t t i n g u p The following instructions will help you set up your air conditioning unit as efficiently as possible. • With a double casement window, use the AIR CONDITIONING WITHOUT INSTALLATION suckers provided to hold the two hal- FOR INSTANT TEMPORARY USAGE...
  • Page 4: Air Conditioning With Installation

    GB-5751010800 26-01-2004 16:27 Pagina 19 S e t t i n g u p AIR CONDITIONING WITH INSTALLATION • Fit the flange supplied to the hole. For more efficient use Pinguino can also be • Fix the hose to the coupling on the semi-permanently installed back of the unit (figure A).
  • Page 5 GB-5751010800 26-01-2004 16:27 Pagina 20 Pre p a ra t i o n f o r u s e HOW TO USE THE AIRCONDITIONER WITH WATER These air conditioners can use both air and water to cool the condenser (the hot part) of the air conditioner.
  • Page 6 GB-5751010800 26-01-2004 16:27 Pagina 21 Turning on and setting the timer SETTING THE TIMER ELECTRICAL CONNECTION Before plugging in check that: The programmer/timer , like all clocks, • the mains supply corresponds to the must be set to the exact time. If for example it is 4.00 pm.
  • Page 7 GB-5751010800 26-01-2004 16:27 Pagina 22 S e l e c t i n g f u n c t i o n s AIR CONDITIONING FUNCTIONS Press the Turbo Power button . The activa- To turn the unit on in air conditioning mode, tion of the function will be signaled when the warning light turns on.
  • Page 8 GB-5751010800 26-01-2004 16:27 Pagina 23 R e c o m m e n d a t i o n s PROBLEM WARNING LIGHT window to guarantee an adequate exchange of air. The lighted pilot light indicates that the • Protect the room from direct exposure to safety device of the pressure switch has swit- the sun’s rays by drawing the curtains ched on.
  • Page 9: Cleaning The Appliance

    GB-5751010800 26-01-2004 16:27 Pagina 24 M a i n t e n a n c e Before cleaning or maintenance, always turn the Purification filter unit off by placing the selector in the “O” position Clean the external side of the purification fil- ter once a week.
  • Page 10 GB-5751010800 26-01-2004 16:27 Pagina 25 De s c a l i n g When the scale deposits become excessive (on average, after about 400 hours of opera- tion) or in any case, at least once each sea- son, it is very important to proceed with the decalcification of the appliance as described below.
  • Page 11: Troubleshooting

    GB-5751010800 26-01-2004 16:27 Pagina 26 Troubleshooting If the unit is not working properly, this may be due to small problems that you can easily resolve yourself. Follow these instructions carefully before contacting your local Authorised Technical Service Centre. PROBLEM CAUSE REMEDY •...
  • Page 12: Technical Specification

    GB-5751010800 26-01-2004 16:27 Pagina 27 Technical specification TECHNICAL SPECIFICATION Power supply see rating plate Max. absorbed power in air conditioning “ Refrigerating capacity “ Refrigerant “ Number of fan speeds Max. air flow . 370 m Dimensions: RECOMMENDED OPERATING CONDITIONS •...