To re-connect the detached ends of the sheath to
the internal unit, you must repeat operations 1
through 7 in reverse order, being careful to
observe the following precautions:
Before drawing the sheath through the hole in
the wall, you should wrap the threaded ends of
the speedy couplings with friction tape or the
like as a protective measure.
Fit the upper two cooling junctures into the two
lower ones and hand-screw them several turns
while checking to be certain they are well-fit-
ted, and then tighten them with the wrenches
used earlier.
After having hooked up the two cooling junc-
tures, tighten the U bolts.
Check the grip on the cooling junctures by wet-
ting the joints with a little soapy water.
No bubbles should appear.
Caution:
We recommend that the disconnecting and con-
necting of the rapid couplings be carried out only
by qualified technicians.
INTERNAL UNIT
Install the internal unit inside the room to be air-
conditioned. This is usually done under a window
or at least close to an outside wall.
The internal unit must be placed "on the level",
with the help of the castor-stops provided. No
obstacles should block this unit's in-take (suction
grille) or out-take (outlet grille) areas.
EXTERNAL UNIT
The external unit may be placed on a terrace or
balcony, in which case the brackets need not be
used.
The external unit can be attached to a wall with the
accessories included as follows:
1) Attach the bracket to the
wall while taking care to
place it as indicated in the
drawing. Use the included
template located on the
plastic cover in order to drill
the holes.
20
9:12
Pagina 20
2) Screw the support blocks
to the external unit with
the
included
M4mm
screws while taking care
to place them so that the
hole for the screws is on
the upper side.
3) Attach the external unit to
the bracket by means of
the M6mm screws.
For temporary installation it is possible to hang the
external unit as illustrated in the drawing. In this
case, use the included straps by attaching them to
the eye hooks. Before inserting the eye hooks
remove the rubber plugs.
The external unit may be installed above or at the
same height as the internal unit, on the condition
that the difference is no more than 1.5 m.
The suction and air-delivery portions of external
unit must not be blocked by obstacles of any
nature.
The distance between the back of the appliance
and the wall must be six (6) cm.
The condensation which forms while this appli-
ance is running (summertime operations) is dis-
posed of by evaporation from the external unit.
If the humidity is too high (in special cases), you
must use the drainage coupling provided to get rid
of condensation. This device must be mounted on
the bottom of the
external unit (see
drawing) after the
rubber
plug
has
been removed.
We strongly recom-
mend that you pro-
tect the external unit
from
rain,
snow,
direct sunlight and
water dripping from
the roof.
2
1
Gasket
Castor
Drainage
Coupling