3.1 MAINTENANCE SCHEDULE
Follow the calendar intervals. More frequent service is required when operating in adverse conditions noted below.
Operation Maintenance
Check Oil Level
Service Air Pre-Cleaner
Change Oil and Oil Filter‡
Clean Spark Arrestor Screen
Adjust Valve Clearance
Service Air Cleaner
Replace Spark Plugs
‡
Change oil after first 8 hours of operation then every season.
*
Change oil and oil filter every month when operating under heavy load or in high temperatures.
**
Clean more often under dirty or dusty operating conditions. Replace air cleaner parts if very dirty..
PRODUCT SPECIFICATIONS
3.2.1 GENERATOR SPECIFICATIONS
MODEL
Model #
Rated Max. Power
Surge Power
Rated AC Voltage
Rated Max AC Load
Current @ 240V
Current @ 120V
Rated Frequency
Phase
Rated DC Voltage
Rated Max DC Load
Current @ 12 Volts
3.2.2 ENGINE SPECIFICATIONS
Rated Horsepower
@ 3600 RPM
Displacement
Spark Plug Type
Spark Plug Gap
Gasoline Capacity
Oil Type
Oil Capacity
Run Time/Fuel
Consumption-1/2 Load
14
Section 3 — Maintenance
Commercial-Industrial-Residential Portable Generator System
Daily
✓
Every Season
✓
**
GPS 12500
004451-1
12.5 kW
18.75 kW
120/240
52.0 Amps
104.0 Amps
60 Hz @3600 RPM
Single Phase
12 Volts
10 Amperes
27
760cc
Champion RC12YC or Equivalent
0.030 inch or (0.76 mm)
16 U.S. gallons
Summer – SAE 30 or 10W-30 Winter – Synthetic 5W-20 or 5W-30
w/Filter Change = 1.5 Qts. w/o Filter Change = 1.2 Qts.
10 Hours / 1.6 gallons per hour
Every Season
Every Season
✓
✓
GPS 15000
004582-1
15.0 kW
22.5 kW
120/240
62.5 Amps
125.0 Amps
30
992cc
✓
*
✓
**
✓
Need help?
Do you have a question about the GUARDIAN RV ULTRA SOURCE 004451 and is the answer not in the manual?