Electrical Connection - Electrolux EGL6282NOX User Manual

Mixed hob
Hide thumbs Also See for EGL6282NOX:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 51
64 www.electrolux.com
1.
Light the burner.
2.
Turn the knob on the minimum posi-
tion.
3.
Remove the knob.
4.
With a thin screwdriver, adjust the by-
pass screw position.
A
A)
The by-pass screw
• If you change from natural gas G20 20
mbar to liquid gas, fully tighten the ad-
justment screw in.
• If you change from liquid gas to natural
gas G20 20 mbar, undo the by-pass
screw approximately 1/4 of a turn.
WARNING!
Make sure the flame does not go
out when you quickly turn the knob
from the maximum position to the
minimum position.

ELECTRICAL CONNECTION

• Ground the appliance according to safe-
ty precautions.
• Make sure that the rated voltage and
type of power on the rating plate agree
with the voltage and the power of the lo-
cal power supply.
• This appliance is supplied with a mains
cable. It has to be supplied with a cor-
rect plug, able to support the load
marked on the rating plate. The plug has
to be fitted in a correct socket.
• Any electrical component must be instal-
led or replaced by the Service Force
Centre technician or qualified service
personnel.
• Always use a correctly installed shock-
proof socket.
• Make sure that there is an access to the
mains plug after installation.
• Do not pull the mains cable to discon-
nect the appliance. Always pull the
mains plug.
• The appliance must not be connected
with an extension cable, an adapter or a
multiple connection (risk of fire). Check
that the ground connection is in con-
formity with the standard and regulations
force.
• The power cable must be placed in such
a way that it does not touch any hot
part.
• Connect the appliance to the mains with
a device that lets to disconnect the ap-
pliance from the mains at all poles with a
contact opening width of minimum 3
mm, eg. automatic line protecting cut-
out, earth leakage trips or fuse.
• None of a parts of the connection cable
can not get a temperature 90 °C. The
blue neutral cable must be connected to
the terminal block label with "N". The
brown (or black) phase cable (fitted in
the terminal block contact marked with
"L") must always be connected to the
live phase.
REPLACEMENT OF THE
CONNECTION CABLE
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to
the voltage and the working temperature.
The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown (or
black) phase wire.
BUILDING IN
min.
450 mm
min.
55 mm
30 mm
480 mm
min.
650 mm
560 mm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Egl6282Egl6382

Table of Contents