Instructions for the installer

IMPORTANT: This appliance can only be installed and
used in permanently ventilated places.
Appliance installation and connection to the power
supply must only be carried out by QUALIFIED
PERSONNEL. Before carrying out any operation,
make sure the appliance is DISCONNECTED from
the power supply.
THE MANUFACTURER DECLINES ANY LIABILITY
FOR POSSIBLE DAMAGE DUE TO INSTALLATION
NOT COMPLYING WITH THE CURRENT
STANDARDS OR FAILURE TO RESPECT THE
ACCIDENT-PREVENTION REGULATIONS.
Gas supply connection
The gas connection must be carried out in compliance
with the current regulations. The appliances leave the fac-
tory, tested and adjusted for the type of gas specified on
the plate located in the bottom protection, near the gas
connection pipe. Make sure the type of gas used is the
same as that specified on the plate. Otherwise, proceed
according to the instructions given in the section "Convert-
ing to different types of gas". To ensure maximum efficiency
and lower consumption, make sure the gas supply pres-
sure respects the values given in the "Burner specifications"
table.
The union is fitted on the end part of the gas train, with a G
1/2" threaded nut, interposing the seal between the com-
ponents as shown in Fig. 12. Screw the parts without forc-
ing, turn the union in the required direction, then tighten
everything.

Electrical connection

The appliance is arranged to operate on a 230 V single-
phase power supply. Connection must be made in
compliance with current standards and regulations.
Before carrying out the connection, make sure:
the limiter valve and the electrical system can take the
appliance load (refer to the serial no. plate);
the supply system is equipped with an efficient earth
connection in compliance with current standards;
the socket or omnipolar switch used are easily
accessible with the appliance installed.
Fit the cable with a plug suitable for the load and connect
it to a suitable safety socket.
To connect directly to the mains, a suitable omnipolar
switch with contact gap of at least 3 mm complying with
Connection
Make the connection to the gas system using a rigid
metal pipe and fittings complying with the current stan-
dards, or with a s/steel flexible tube complying with the
current standards, limited to those not longer than 2 m.
When using flexible metal tubes make sure they are not in
contact with movable parts or squashed. Pay the same at-
tention also when an oven and top combination is provided
for. The gas inlet union for the appliances is 1/2" cylindrical
male thread.
Make the connection, avoiding any kind of stress on the
appliance.
IMPORTANT: After installation, always check the
perfect seal of all unions using a soapy solution.
Never carry out this check with a flame.
FO 0264
current standards must be installed between the
appliance and the network. The yellow/green earth wire
must not be interrupted by the switch.
The brown phase wire (coming from terminal "L" on the
terminal block) must always be connected to the power
supply phase wire.
In any case the power cable must be positioned in such
a way that no part of it reaches a temperature of more
than 90°C.
An example of an optimum path is given in Fig. 15. The
cable is guided by means of clamps fixed to the side of
the cabinet, in order to avoid any contact with the
equipment beneath the cooktop.
A) Gas train end with nut
B) Seal
C) Adjustable union
Fig. 12