Fix lower bracket (with two fixing
holes) to the floor then measure
the height from floor level to
engagement edge on back of
appliance, dimension ' C' of Fig.
3b.
4. Assemble upper bracket to lower
bracket so that the underside of
bracket is dimension ' C' + 3mm
above floor level. (See Fig. 3b).
Reposition appliance and check
that top bracket engages into
appliance back as shown in Fig.
3b.

The battery

1. The battery is located on the left
hand side of the front plinth.
2. To gain assess to the battery,
open the main oven door and lift
up the battery holder lid.
3. Fit the new battery ensuring (+)
terminal is next to the (+) sign on
the battery. See Fig. 4.
4. Close the lid of the battery
holder.
Pressure testing
1. The oven injector is used as a
pressure test point.
Remove the oven furniture.
Remove
oven
retaining clips (one spring clip
from each side) and remove box
front cover.
Replace one clip back into the
right hand side of the burner box.
Remove
oven
removing the spring clip from the
right hand side of the oven
burner
and
injector, whilst easing it forward
and taking care not to strain the
F.S.D. phial.
burner
box
burner
slide
burner
off
by
41
Fig.4.