TLG-12SPX4 — OUTPUT TERMINAL PANEL FAMILIARIZATION
120 VAC GFCI Receptacle
This120 VAC, 20 amp GFCI (Duplex Nema 5-20R) receptacle
can be used anytime the generator is in operation. Pressing
the reset button resets the GFCI receptacle after being tripped.
Pressing the Test Button (See Figure 6) in the center of the
receptacle will check the GFCI function. Both receptacles
should be tested at least once a month.
Figure 6. G.F.C.I. Receptacle
Twist Lock Dual Voltage 120/240 VAC Receptacle (Option)
There is one CS-6369 120/240V, 50 amp auxilliary twist-lock
receptacle (Figure 7) provided on the output terminal panel.
This receptacle is protected by a 50 amp circuit breaker.
Figure 7. 120/240V CS6369 Twist-Lock
Auxiliary Receptacle
PAGE 22 — TLG-12SPX4— OPERATION AND PARTS MANUAL — REV. #1 (12/17/09)
L5-30R Twist Lock 120 VAC Receptacle (Option)
There is one L5-30R, 120 VAC 30 amp auxilliary twist-lock
receptacle (Figure 8) provided on the output terminal panel.
Figure 8. 120 VAC L5-30R Twist-Lock
Auxiliary Receptacle
L6-30R Twist Lock 240 VAC Receptacle (Option)
There is one L6-30R, 240 VAC 30 amp auxilliary twist-lock
receptacle (Figure 9) provided on the output terminal panel.
Figure 9. 240 VAC L6-30R Twist-Lock
Auxiliary Receptacle
Turn the voltage regulator control knob (Figure 10) on the
control panel to obtain the desired voltage. Turning the knob
clockwise will increase the voltage, turning the knob counter-
clockwise will decrease the voltage.
Figure 10. Voltage Regulator Control Knob