Introduction & Specifications - Dyna-Glo Series User Manual

Propane construction heater
Table of Contents

Advertisement

Dyna-Glo ProPane ForceD air construction Heaters
The heater is designed and approved for use as a construction heater under anSi z83.7a, CSa 2.14a.
it is hard to anticipate every use which may be made of this heater.
FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS.
other standards govern the use of fuel gases and heat producing products in specific applications.
your local authority can advise you about these.
IMPORTANT: read ThiS uSer'S Manual CareFully and CoMpleTely BeFore Trying
To operaTe or ServiCe ThiS heaTer. iMproper uSe oF ThiS heaTer Can CauSe
SeriouS injury or deaTh FroM Fire, exploSion and CarBon Monoxide poiSoning.
This is a direct-fired forced air construction heater for either indoor construction or outdoor use. its intended
use is primarily the temporary heating of buildings or structures under construction, alteration or repair. all the
products of combustion generated by the heater are forced through the heater and released into the area being
heated. This heater operates at approximately 98%+ combustion efficiency but still produces a small amount
of carbon monoxide. humans can tolerate small amounts of carbon monoxide for short periods. Carbon
monoxide can build up in a heated space and failure to provide adequate ventilation could result in poisoning
or death.
Model   N o.
RMC-­‐FA40                                
DG/DGD/
DGP/DGP-­‐01
Input   R aFng
40,000   B TU/hr
Type   o f   G as
Propane
Gas   S upply   P ressure  
to   R egulator  
Cylinder   P ressure
Maximum
Minimum   ( for  
purpose       o f   I nput  
5psig
Adjustment)
Manifold   P ressure
11"   W .C
Gas   C onsumpFon
1.9lbs/hr
Electrical   I nput
120V,   6 0Hz,   1 Ø  
Amperage     L oad
0.68amps
    U nload
3550rpm
Fan
    L oad
3000rpm
IgniFon
Piezo/Manual   S park ConMnuous   S park
Spark   G ap
0.16"   ( 4mm)
19.3"x8.3"x15.2"
Size   ( LxWxH)
(490x211x386)mm
13.7lbs/14lbs
Weight
(6.2kg/6.35kg)
3
PROPANE CONSTRUCTION HEATER
WARNING
: noT For uSe wiTh duCT work.
sPeciFications
RMC-­‐FA50                                    
DG/DGD/DGP-­‐01
RMC-­‐FA50A
30,000   B TU/hr
50,000   B TU/hr
Propane
Cylinder   P ressure
5psig
11"   W .C
1.4lbs/hr
2.3lbs/hr
120V,   6 0Hz,   1 Ø  
0.65amps
3570rpm
3300rpm
0.16"   ( 4mm)
19.3"x8.3"x15.2"
(490x211x386)mm
14.3lbs   ( 6.48kg)
RMC-­‐FA60                                              
RMC-­‐FA100                      
DGD/DGP/DGP-­‐01
DG/DGD/DGP/DGP-­‐
01
RMC-­‐FA100A
30,000   B TU/hr
70,000   B TU/hr
60,000   B TU/hr
100,000   B TU/hr
Propane
Propane
Cylinder   P ressure
Cylinder   P ressure
5psig
5psig
11"   W .C
11"   W .C
1.4lbs/hr
3.3lbs/hr
2.8lbs/hr
4.6lbs/hr
120V,   6 0Hz,   1 Ø  
120V,   6 0Hz,   1 Ø  
0.65amps
0.7amps
3570rpm
3580rpm
3300rpm
3300rpm
ConMnuous   S park
ConMnuous   S park
0.16"   ( 4mm)
0.16"   ( 4mm)
25.6"x12.7"x15.6"
19.3"x8.3"x15.2"
(650x323x396)mm
(490x211x386)mm
25.6"x11.8"x16.1"
(650x300x409)mm
21.5lbs/21lbs/20.8lbs
14.3lbs   ( 6.48kg)
(9.75kg/9.5kg/9.4kg)
CHECK WITH YOUR LOCAL
RMC-­‐FA125      
DGD/DGP/DGP-­‐01
70,000   B TU/hr
125,000   B TU/hr
Propane
Cylinder   P ressure
5psig
11"   W .C
3.3lbs/hr
5.8lbs/hr
120V,   6 0Hz,   1 Ø  
0.7amps
3580rpm
3300rpm
ConMnuous   S park
0.16"   ( 4mm)
25.6"x12.7"x15.6"
(650x323x396)mm
25.6"x11.8"x16.1"
(650x300x409)mm
21.5lbs/21lbs/20.8lbs
(9.75kg/9.5kg/9.4kg)
RMC-­‐FA150                              
DG/DGD
RMC-­‐FA150A
120,000   B TU/hr
150,000   B TU/hr
Propane
Cylinder   P ressure
5psig
11"   W .C
5.6lbs/hr
7.0lbs/hr
120V,   6 0Hz,   1 Ø  
0.7amps
3580rpm
3300rpm
ConMnuous   S park
0.11"   ( 2.8mm)
25.6"x11.8"x16.1"
(650x300x409)mm
21.2lbs   ( 9.6kg)