Dyna-Glo  Series User Manual

Dyna-Glo Series User Manual

Propane construction heater

Advertisement

USER'S MANUAL AND OPERATING INSTRUCTIONS
Dyna-Glo™
MODELS:
Dyna-Glo™Professional
MODELS:
C
CSA 2.14a-2007, ANSI Z83.7a-2007
GHP Group, Inc.
8280 austin ave.
GHP
Morton grove, il 60053-3207
8280 Austin Avenue
M o r t o n G rove , I L .
6 0 0 5 3 - 3 2 0 7
Tel: ( 847 ) 324 - 5900
Fax: ( 847 ) 324 - 5901
Toll Free (877) GHP Group
( 8 7 7 ) 4 4 7 - 4 7 6 8
www.ghpgroupinc.com
GENERAL HAZARD WARNING
Failure To CoMply wiTh The preCauTionS and inSTruCTionS provided wiTh
ThiS heaTer, Can reSulT in deaTh, SeriouS Bodily injury and properTy loSS,
or daMage FroM The hazardS oF Fire, exploSion, Burn. aSphyxiaTion, CarBon
Monoxide poiSoning, and/or eleCTriCal ShoCk.
only perSonS who Can underSTand and Follow The inSTruCTionS Should
uSe or ServiCe ThiS heaTer.
iF you need aSSiSTanCe or heaTer inForMaTion SuCh aS an inSTruCTion
Manual, laBelS, eTCeTera, ConTaCT The ManuFaCTurer.
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 877-447-4768 8:30 a.m. – 4:30 pm CST, Monday – Friday
50-10-104
RMC-FA40/DG/DGD
RMC-FA50/A/DG/DGD
RMC-FA60/DGD
RMC-FA100/A/DG/DGD
RMC-FA125/DGD
RMC-FA150/A/DG/DGD
RMC-FA40/DGP/DGP-01
RMC-FA50/DGP/DGP-01
RMC-FA60/DGP/DGP-01
RMC-FA100/DGP/DGP-01
RMC-FA125/DGP/DGP-01
RMC-FA150/DGP/DGP-01
US
CONSUMER: retain this manual for future reference.
or email us at customerservice@ghpgroupinc.com
PROPANE
CONSTRUCTION HEATER
(40,000 BTU/HR,
(30,000/50,000 BTU/HR,
(30,000/60,000 BTU/HR,
(70,000/100,000 BTU/HR, FORCED - AIR)
(70,000/125,000 BTU/HR, FORCED - AIR)
(120,000/150,000 BTU/HR, FORCED - AIR)
(40,000 BTU/HR,
(30,000/50,000 BTU/HR,
(30,000/60,000 BTU/HR,
(70,000/100,000 BTU/HR, FORCED - AIR)
(70,000/125,000 BTU/HR, FORCED - AIR)
(120,000/150,000 BTU/HR, FORCED - AIR)
www.ghpgroupinc.com
Printed in China
FORCED - AIR)
FORCED - AIR)
FORCED - AIR)
FORCED - AIR)
FORCED - AIR)
FORCED - AIR)
Rev. 0/10

Advertisement

Table of Contents
loading

Summary of Contents for Dyna-Glo Dyna-Glo Series

  • Page 1 6 0 0 5 3 - 3 2 0 7 Tel: ( 847 ) 324 - 5900 Fax: ( 847 ) 324 - 5901 Toll Free (877) GHP Group ( 8 7 7 ) 4 4 7 - 4 7 6 8 www.ghpgroupinc.com...
  • Page 3: Table Of Contents

    M o r t o n G rove , I L . 6 0 0 5 3 - 3 2 0 7 Tel: ( 847 ) 324 - 5900 Fax: ( 847 ) 324 - 5901 Toll Free (877) GHP Group...
  • Page 4: Introduction & Specifications

    PROPANE CONSTRUCTION HEATER Dyna-Glo ProPane ForceD air construction Heaters The heater is designed and approved for use as a construction heater under anSi z83.7a, CSa 2.14a. CHECK WITH YOUR LOCAL it is hard to anticipate every use which may be made of this heater. FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS.
  • Page 5: General Safety Instructions

    PROPANE CONSTRUCTION HEATER General saFety instruction accidents are always tragic especially because so many of them could have been prevented with little care and judgment. There are some basic good practices, we hope you will follow for safe use of your heater. iMPortant saFety instruction •...
  • Page 6: Unpacking Heater

    PROPANE CONSTRUCTION HEATER unPacKinG Heater 1. remove heater from carton. 2. remove all protective packing applied to heater for shipment. 3. retain cartons and packaging material until unit is operated and found in good condition. 4. Check heater for any shipping damage. if heater shows any external or internal damage, promptly inform dealer/distributor where you purchased heater.
  • Page 7 PROPANE CONSTRUCTION HEATER Tools required for assembly: RMC-FA100 DGP/DGP-01 phillips head screw driver RMC-FA125 DGP/DGP-01 and adjustable wrench 1. assemble the leg: parts required: leg 1 pc place the heater as shown, insert the leg into holes of the base, then adjust to the desired height.
  • Page 8: Size & Capacity Of Propane Cylinders

    PROPANE CONSTRUCTION HEATER inForMation on siZe * caPacity oF ProPane Gas cylinDers: The chart below shows the number and size of propane tanks needed to run this heater. *less gas is vaporized at lower temperatures. you may need two or more 100 pound tanks or one larger tank in colder weather. (See the parts list for your model of heater to get the specified regulator assembly.) number of Tanks Temperature...
  • Page 9: Installation To The Propane Gas Tank

    PROPANE CONSTRUCTION HEATER installation to tHe ProPane Gas tanK IMPORTANT: you must use a propane/lp gas supply cylinder that is compatible with the connection device provided with the hose and regulator. propane/lp regulator Supply valve Fuel gas propane/lp Fitting hose to Tank heater FIGURE 2...
  • Page 10: Leak Checking & Positioning Heater

    PROPANE CONSTRUCTION HEATER ProPane saFety propane is safe to use when properly handled. Careless handling of the propane gas tank could result in fire and/or an explosion. Therefore: • always keep tank/cylinder securely fastened in an upright position. • avoid tipping tank on its side when connected to a regulator since this may cause damage to diaphragm in regulator.
  • Page 11: Test Firing Heater & Storage

    PROPANE CONSTRUCTION HEATER sHutDoWn instructions WARNING : Motor and fan must be running before lighting, during operation and at shutdown, in order to prevent a flame-out condition which could result in personal injury or property damage. Turn gas valve knob clockwise to oFF position. Turn gas supply oFF by turning propane tank valve clockwise to close.
  • Page 12: Wiring Diagrams

    PROPANE CONSTRUCTION HEATER WirinG DiaGraMs...
  • Page 13: Wiring Diagrams

    PROPANE CONSTRUCTION HEATER WirinG DiaGraMs 100K,125K & 150K Models only 100K,125K & 150KSólo modelos 100K,125K & 150K Les modèles Seulement...
  • Page 14: Replacement Parts List

    PROPANE CONSTRUCTION HEATER rePlaceMent Parts list PART NUMBER ITEM DESCRIPTION 40 SERIES 50 SERIES 60 SERIES INNER SHELL ASS' Y 2304818 2304818 2304818 NOZZLE 2304829 2304942 2325121 FLAME HOLDER CAP 2304819 2304819 2325120 THERMAL SWITCH BRKT. 2304826 2304826 2304826 THERMAL SWITCH 2201373 2201563 2201599...
  • Page 15: Rmc-Fa60/Dgd/Dgp/Dgp-01

    PROPANE CONSTRUCTION HEATER rePlaceMent Parts list MODELS: RMC-FA40/DG/DGD/DGP/DGP-01 RMC-FA50/DG/DGD/DGP/DGP-01 RMC-FA60/DGD/DGP/DGP-01...
  • Page 16 PROPANE CONSTRUCTION HEATER rePlaceMent Parts list PART NUMBER ITEM DESCRIPTION 100 SERIES 125 SERIES 150 SERIES (EX. C/L/DGP) (EX. C/L/DGP) INNER SHELL ASS' Y 2304929 2304929 2304929 NOZZLE 2304943 5030077 2304944 FLAME HOLDER CAP 2304930 2325122 2304931 THERMAL SWITCH BRKT. 2304826 2315515 2001355...
  • Page 17: Rmc-Fa150/Dg/Dgd/Dgp/Dgp-01

    PROPANE CONSTRUCTION HEATER ProPane construction Heater illustrateD / Parts breaKDoWn MODELS: RMC-FA100/DG/DGD/DGP/DGP-01 RMC-FA125/DGD/DGP/DGP-01 RMC-FA150/DG/DGD/DGP/DGP-01...
  • Page 18: Replacement Parts List

    PROPANE CONSTRUCTION HEATER rePlaceMent Parts list PART   N UMBER DESCRIPTION ITEM           FA100   D GP FA125DGP No.   INNER   S HELL     A SS'   Y 2304929 2304929 NOZZLE 2304943...
  • Page 19: Rmc-Fa100/Dgp/Dgp-01 / Rmc-Fa125/Dgp/Dg P-01

    PROPANE CONSTRUCTION HEATER ProPane construction Heater illustrateD / Parts breaKDoWn MODELS: RMC-FA100/DGP/DGP-01 RMC-FA125/DGP/DGP-01...
  • Page 20 THIS PAGE INTENTIONALLY LEFT BLANK...
  • Page 21: Warranty

    This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any defect in materials and workmanship for a period of one (1) year from the date of retail sale. GHP Group, Inc., at it’s option, will either provide replacement parts or replace or repair the unit, when properly returned to the retailer where purchased or one of our service centers as directed by GHP Group, Inc., within one (1) year of retail purchase.
  • Page 22: Warranty Registration

    6 0 0 5 3 - 3 2 0 7 Tel: ( 847 ) 324 - 5900 Fax: ( 847 ) 324 - 5901 SAVE THIS CARD! Toll Free (877) GHP Group ( 8 7 7 ) 4 4 7 - 4 7 6 8 www.ghpgroupinc.com Place...

Table of Contents