Physical Disk Related Issues - Dell 6 series User Manual

Poweredge expandable raid controller
Table of Contents

Advertisement

Physical Disk Related Issues

Table 7-4 describes physical disk-related problems you might encounter, with
suggested solutions.
Table 7-4. Physical Disk Issues
Problem
One of the physical disks in
the disk array is in the
failed state.
Cannot rebuild a fault
tolerant virtual disk.
NOTE:
For more
information, see the alert
log for virtual disks.
Fatal error(s) or data
corruption(s) are reported
when accessing virtual
disks.
122
Troubleshooting
Suggested Solution
Perform the following actions to resolve this problem:
Check the backplane for damage.
1
Check the SAS cables.
2
Reseat the physical disk.
3
Contact Dell Technical Support if the problem persists.
4
The replacement disk is too small or not compatible
with the virtual disk. Replace the failed disk with a
compatible good physical disk with equal or greater
capacity.
Contact Dell Technical Support.