Dell 5 series User Manual page 38

Expandable raid controller
Hide thumbs Also See for 5 series:
Table of Contents

Advertisement

3 Determine whether the dirty cache LED on the controller is illuminated.
If the LED is illuminated, replace the system cover, reconnect the system to power, turn on the
system, and repeat step 1 and step 2. See Figure 3-10.
NOTE:
The location of the PERC 5/i varies from system to system. See the Hardware Owner's Manual
included with the system for specific information on where the PERC 5/i is located.
If the LED is not illuminated, continue with the next step.
Figure 3-10. PERC 5/i Adapter Dirty Cache LED Location
4 Disconnect the data cables and battery cable from the PERC 5/i.
5 Remove any retention mechanism, such as a bracket screw, that might be holding the PERC 5/i in the
system, and gently lift the controller from the system's PCI-E slot. See Figure 3-11.
36
Hardware Installation and Configuration
bracket screw
memory module
PERC 5/i Adapter
dirty cache LED

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge 5/ePoweredge 5/i

Table of Contents