Disconnecting the BBU from a PERC 5/i Adapter or a PERC 5/i

NOTE:
A PERC 5/i Adapter installed in a Dell Precision workstation or a PowerEdge SC server does not have a BBU.
This section describes how to disconnect the BBU on a PERC 5/i Adapter or a PERC 5/i while the
adapter or controller is installed in a system.
1 Perform a controlled shutdown on the system in which the PERC 5/i is installed.
2 Disconnect the system from the electrical outlet and remove the system cover.
CAUTION:
NOTE:
For more information on removing and replacing the system cover, see the Hardware Owner's Manual
that shipped with the system.
3 Determine whether the dirty cache LED on the controller is illuminated.
If the LED is illuminated, replace the system cover, reconnect the system to power, turn on the
system, and repeat step 1 and step 2. See Figure 3-10.
NOTE:
that shipped with the system for specific information on where the PERC 5/i is located.
If the LED is not illuminated, continue with the next step.
4 Locate the battery cable connection next to the DIMM on the controller, and disconnect the battery.
38
Hardware Installation and Configuration
Running a system without the system cover installed can cause damage due to improper cooling.
The location of the PERC 5/i varies from system to system. See the Hardware Owner's Manual