Stud Internal Wiring Schematic; Component Resistance Values - Westerbeke 8.0KW-60Hz Service Manual

Single and three phase marine diesel generators
Hide thumbs Also See for 8.0KW-60Hz:
Table of Contents

Advertisement

BT GENERATOR 12 STUD INTERNAL WIRING SCHEMATIC
NOTE:
Refer to the text and diagramsjor the proper method of testing for resistance and continuity.
A
+
r-------------..-,
:
1
AErO
S
:
i
I
:
{>r
4
31
I
2
I
I
I
L _ _ _ _ _ _ _ _ _ _ _ _ _ J
G
ORANGE
+
AC
BLACK
6
5
9
3
2
7
8
-Kl-
L -________
~~--~
AC~~~------------------------------~
GREEN
YelLOW
COMPONENT RESISTANCE VALUES [OHMS]
A EXCITER STATOR WINDINGS
10.0Q
8 AUXILIARY ROTOR WINDINGS (A,8,C) __ 1.0-1.2Q
DIODES (6)
11Q/infinite
ROTATING FIELD WINDINGS
7.0-8.0Q
POSI RESISTOR)
infinite
C
MAIN STATDR WINDINGS
20-22Q
MAIN STATOR AUXILIARY WINDlNGS_1.5-1.8Q
o
COMPOUND TRANSFORMER WINDlNGL.019-.021Q
COMPOUND TRANSFORMER
AUXILIARY WINDINGS
4.0-4.5Q
G BRIDGE RECTIFIER
BRIDGE
RECTIFIER
AC TERMINAL
BOARO
CONNECTION
1-2+3
[VOLTAGE HERTZ
CONNECTION]
-.Y"
WESTERBEKE
Engines & Generators
77
8T GENERATOR SINGLE PHASE 12 STUD
COMPO UNO
TRANSFORMER
'em,e"OT
BREAKER
'''''lem1"
TERMINAL 1 & 4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents