Timer/Softener, Service Checkout Procedure
If you are not getting soft water, and an error code is not displayed, use the procedures below
to find the problem. First make the following visual checks.
VISUAL CHECKS:
Is there electrical power to the outlet the water softening system
1
transformer is plugged into?
Is there sufficient salt in the storage tank?
2
Is the plumbing bypass valve directing water for soft water
3
service?
Is the valve drain hose open to the drain, not elevated too high,
4
and unobstructed?
If you do not find a problem with the visual checks, continue below.
NO SOFT
TIMER SHOWS WRONG
TIME AND DAY, AND/OR
WATER
IS FLASHING.
Check electrical
power to control
TIMER
(outlet, transformer,
DISPLAY
power cable, all
BLANK.
connections).
TIMER DISPLAY SHOWS
CORRECT TIME AND DAY
AND IS STEADY.
Electrical power was off.
Reset the correct time of
day.
NO POWER
POWER OK
Do manual
diagnostics.
Investigate reason for
power loss.
REPAIR AS
Do manual
NEEDED
diagnostics to
verify proper
function.
TIMER
DEFECTIVE
17