Setting Range - Omron SYSDRIVE 3G3EV SERIES User Manual

Sysmac bus model compact low-noise inverter
Hide thumbs Also See for SYSDRIVE 3G3EV SERIES:
Table of Contents

Advertisement

Setting range

This constant is used to select the stop mode to be invoked when the STOP/RESET key
is pressed or when bit 0 of Unit n + 1 (run command) is set to 0.
Value
0
Deceleration stop
1
Free running
Forward/Reverse Rotation Selection
Setting range
Value
Forward rotation
Reverse rotation
Note 1. While the Inverter is being operated with the Digital Operator, the direction of
motor rotation can be changed by lighting the F/R indicator with the Mode Key
first, pressing the Increment or Decrement Key to change the setting, then
pressing the Enter Key.
Note 2. The direction (forward/reverse) of motor rotation depends on the motor model
used. Refer to the instruction manual for the motor.
Stop Mode Selection
0, 1
,
Factory setting 0
Description
Factory setting
Description
Chapter 4
(forward rota-
tion)