always shield your eyes when
working near batteries. In case
of contact, administer the fol-
lowing FIRST AID.
• EXTERNAL: Flush with plen-
ty of water.
• INTERNAL: Drink large quan-
tities of water or milk and im-
mediately call a physician.
• EYES: Flush with water for
15 minutes and seek prompt
medical attention.
Batteries produce explosive
hydrogen gas. Therefore, keep
sparks, fl ames, cigarettes, etc.,
away from the battery and pro-
vide suffi cient ventilation when
charging it in an enclosed
space.
KEEP THIS AND ALL BATTER-
IES OUT OF THE REACH OF
CHILDREN.
NOTICE
Never attempt to remove the bat-
tery cell seals, as this would per-
PERIODIC MAINTENANCE AND ADJUSTMENT
manently damage the battery.
The battery is located behind panel A.
Remove the panel to access the bat-
tery. (See page 6-7.)
To charge the battery
Have a Yamaha dealer charge the
battery as soon as possible if it seems
to have discharged. Keep in mind that
the battery tends to discharge more
quickly if the vehicle is equipped with
optional electrical accessories.
NOTICE
To charge a VRLA (Valve Regu-
lated Lead Acid) battery, a special
(constant-voltage) battery charger
is required. Using a conventional
battery charger will damage the
battery.
To store the battery
ECA10620
1. If the vehicle will not be used for
more than one month, remove
the battery, fully charge it, and
then place it in a cool, dry place.
6-26
NOTICE: When removing the
battery, be sure the key is
turned to "OFF", then discon-
nect the negative lead before
disconnecting the positive
lead.
[ECA16302]
2. If the battery will be stored for
more than two months, check it
at least once a month and fully
charge it if necessary.
3. Fully charge the battery before
installing it. NOTICE: When in-
stalling the battery, be sure the
key is turned to "OFF", then
ECA16521
connect the positive lead be-
fore connecting the negative
lead.
[ECA16840]
4. After installing the battery, make
sure that the battery leads are
properly connected to the battery
terminals.
5. Turn the key from "ON" to "OFF"
three times in three-second in-
tervals to initialize the idle speed
control system.