D-Link ShareCenter Pulse DNS-320 User Manual page 14

Hide thumbs Also See for ShareCenter Pulse DNS-320:
Table of Contents

Advertisement

D-Link ShareCenter Pulse User Manual
Step 5:
The four options are: Standard, JBOD, RAID 0 and
RAID 1.
JBOD - Combines both hard drives in a linear fashion
which will create one large volume geared towards
maximum available space.
RAID 0 - Combines both hard drives in a striped fashion
which will create one large volume geared towards
maximum performance.
RAID 1 - Mirrors the hard drives for redundancy. If
one hard drive fails, the other still contains all of the
data. Replace the failed hard drive and it will re-mirror,
restoring data protection.
Standard - Creates two separate volumes (or one
volume if only one hard drive is present). Each hard drive
is its own volume.
When prompted to configure the Hard Drive Settings:
Select the type of hard drive configuration. In this
configuration we'll use RAID 1 as the example
configuration.
Step 6:
Auto-rebuild is a feature that allows the ShareCenter
Pulse to initiate the rebuilding phase automatically. The
rebuilding phase will occur when one or more hard drives
fail and is replaced by a new one.
WARNING - This feature will automatically format the
newly added drive. If this feature is NOT required, click
disable.
Click 'Next' to continue.