User Priority Access Table; Keyboard Operation; Keyboard Operation General; System Commands - Bosch LTC 8900 Series User Manual

Allegiant microprocessorbased video switcher/control systems cpu firmware version 10.0
Hide thumbs Also See for LTC 8900 Series:
Table of Contents

Advertisement

LTC 8900 | User Manual | Keyboard Operation
4.1

User Priority Access Table

The following table shows system function access for
the 64 levels of users.
System Function
Switch Video On Monitors
Control Pan/Tilt/Zoom Camera
Lock Monitor
Lock Pan/Tilt/Zoom Camera
Acknowledge Alarms
Perform Keyboard Test
Show Keyboard Number
Activate Keyboard Beeper
Change User Password
Program Sequences
Position Video Overlay Display
Set Overlay Display Brightness
Select Overlay Display Type
Set System Time/Date
Program Pre-positions
Set Time/Date Format
Set Camera and Monitor Titles
Enable Time Events
Enable 3-line Title Mode
Enable 6-digit Camera ID Mode
Enable Vertical Phase Set
Reset System
Printout Tables and Sequences
Default Monitor Overlay
Select Alarm Response Mode
Select Printer Mode
Designate Alarm Monitor Type
Select Keyboard Login
Select Console Login
Configure/Reset RS-232 Ports
Bosch Security Systems | March 17, 2009
Priority Levels
1
2 to 7
8 to 64
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
Yes
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
5

KEYBOARD OPERATION

5.1
General
Primary operation of an Allegiant switcher is controlled
via the system keyboard. The 2 types of keyboards
available are:
Conventional LTC 8555 Series (incorporates
LEDs and pushbuttons)
IntuiKey model (uses dynamic LCD menu
screens)
General operation steps for both keyboard models follow.
Refer to the User Manual provided with the keyboard for
additional information.
As the system is supplied from the factory, various user-
selectable features have been set to a default state. Since
these features are user-selectable and can have a
significant effect on the system operation, note any
changes that may be in effect.
5.2

System Commands

5.2.1 Keyboard Login Procedure
Keyboard modes:
Via Factory Default Settings, a keyboard is
ready for use as soon as power is applied to the
system.
The system operator must logon to a keyboard to
access the system. When a system is configured to
use the keyboard logon, operators must be pre-
assigned a user number and password. Up to 128
user numbers are available, each having default
priority level. User specific priority levels can only
be changed via the PC-based LTC 8059 Master
Control Software (MCS) program. Refer to the
MCS manual for details.
If the logon feature is enabled and an operator is not
logged in, LED keyboards show flashing dashes in their
display. IntuiKey keyboards prompt for a user number
when entering the main Allegiant softscreen menu.
EN | 8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents