LTC 8900 | User Manual | Keyboard User Functions
Move the joystick to the left to blank the left-hand side
of the display from the monitor and to the right to
return it. Refer to User Function 5 or 25 to verify
brightness level. Press ENTER to update all system
monitors to the selected format. If using the LTC 8555
Series keyboard, press USER to exit.
6.1.28 User Function 27 -
Select Keyboard Login
This function controls the system s keyboard login
feature. Move the joystick up/down to select the mode
for the system to function in. If the login feature is
enabled (MUST USE KBD PWD is selected), the
system keyboards require each user to login and logoff
the system. All users are required to enter a user
number and correct password to interact with the
system. If the login feature is disabled (NO KBD PWD
LOGIN is selected), system keyboards are always
online with the system.
Once selection is made, exit the User Function mode and
reset the system either via keyboard User Function 15, or
by removing and restoring the main AC power to the
system. Once the system has been reset, the keyboard
login function will be active and all system keyboards
must be logged in to access the system.
6.1.29 User Function 28 -
Select Console Login
This function controls the system s external
Console port login feature. After entering the mode,
move the joystick up/down to select the mode in
which the system should function. If the login feature
is enabled (MUST USE CON PWD is selected), any
external PC or other computing device must login to
communicate with the system. External computing
devices are required to enter a user number and
correct password. If the Console login feature is disabled
(NO CON PWD LOGIN is selected), the Console
port is available for communication.
Once the selection is made, exit the User Function
mode and reset the system, either via keyboard
User Function 15, or by removing and restoring the main
AC power to the system. Once the system has been
reset, the Console login function is active, and all external
computing devices must login to access the system.
6.1.30 User Function 29 -
Reset RS-232 Parameters to Default
This function returns the system s external
RS-232 ports to a known default state. After entering
the mode, enter a valid password. The system will
Bosch Security Systems | March 17, 2009
reset after placing the RS-232 protocols back to the
default state.
6.1.31 User Function 30 -
Set Controller RS-232 Parameters
Priority level 1 users can select the RS-232 baud rate
and handshake options for the system s Controller port
via this function. Upon entry to this mode, the current
settings are displayed. Move the joystick up/down to
select the baud rate, and left/right to select the
handshake option. After being changed, the port is
also automatically set to eight data bits, no parity, and
one stop bit. Once new settings have been selected,
enter the user password and press ENTER. If using
the LTC 8555 Series keyboard, press USER to exit.
6.1.32 User Function 31 -
Set Console RS-232 Parameters
Priority level 1 users can select the RS-232 baud rate
and handshake options for the LTC 8900 system s
Console port via this function. Upon entry to the mode,
the current settings are displayed. Move the joystick
up/down to select the baud rate, and left/right to select
the handshake option. After being changed, the port is
also automatically set to eight data bits, no parity, and
one stop bit. Once new settings have been selected,
enter the user password and press ENTER. If using the
LTC 8555 Series keyboard, press USER to exit.
6.1.33 User Function 32 -
Set Alarm RS-232 Parameters
Priority level 1 users can select the RS-232 baud rate
and handshake options for the LTC 8900 system s
Alarm port via this function. Upon entry to the mode,
the current settings are displayed. Move the joystick
up/down to select the baud rate, and left/right to select
the handshake option. After being changed, the port is
also automatically set to eight data bits, no parity, and
one stop bit. Once new settings have been selected,
enter the user password and press ENTER. If using the
LTC 8555 Series keyboard, press USER to exit.
6.1.34 User Function 33 -
Display User Number and Priority
This function displays the current user s number and
priority level on the monitor screen. The user number
will be displayed on the top line and the user s priority
level will be displayed on the bottom line of the
monitor screen. If using the LTC 8555 Series keyboard,
press USER to exit.