LTC 8900 | User Manual | Error Messages
Error
Description
Error 55 -
The switcher sequence being requested or
SEQUENCE priority
cleared requires monitors that are in use by
a user of equal or higher priority. Contact
a user with higher priority, or have the
system administrator clear the monitors in
question.
Error 56 -
The user has tried to load a sequence that
SEQUENCE request
is being edited in the PROGRAM mode.
Once editing has been completed, the
sequence may be loaded.
Error 58 -
The sequence being requested is a Relative
SEQUENCE request
sequence, and the user is only permitted
access to Absolute sequences.
The user has tried to program a sequence
Error 60 -
PROGRAM request
that is currently running. The sequence
must first be stopped before any editing
can be performed.
The user has tried to program a new
Error 62 -
sequence when the system is out of
PROGRAM request
sequence memory space. Delete unused
sequences and then program the new
sequence.
Some other user is already programming a
Error 63 -
sequence on this monitor.
PROGRAM request
This monitor cannot be used for alarm
Error 70 -
operations; it has not been designated as
Monitor not allocated
alarm-capable by the system programmer.
to alarm monitor
group
Error 71 -
A group of alarm monitors may not have
Step monitor required
an armed Review (display) monitor without
having armed Step (sequence) monitors.
A specific alarm number must be entered
Error 78 -
when arming or disarming an alarm.
Must enter alarm
number
Bosch Security Systems | March 17, 2009
Error
Error 80 -
Trunk not available
Error 81 -
Satellite Trunk Seized
Error 89 -
Internal stack error
Error 90 -
Keyboard entry undefined
Error 92 - Keyboard entry out of
range
Error 94 - Keyboard entry invalid An invalid character has been
Error 95 - Keyboard entry
incomplete
Error 96 - * (STAR) undefined
Warning Messages - Hi/Low Temperature Alert
The Allegiant CPU is equipped with a temperature sensor. If the
ambient CPU temperature drops below -10 degrees C or goes above
+55 degrees C, an on-screen "Temperature Alert" message will appear
on the system monitors and the system keyboards will begin to beep.
EN | 32
Description
An attempt was made to access a
remote camera connected to a
satellite system, but no unused
trunk lines are currently available.
The camera currently viewed has
changed because an operator with
a higher priority has selected a
different camera that seized the
trunk line from the satellite.
A stack overflow has occurred
within the system. Report this to
the manufacturer.
The keyboard entry is not defined.
Check the appropriate section of
this manual for the desired
operation, and try again.
The data entered for a valid
command was not in the permitted
range. Check the appropriate
section of this manual for the
acceptable ranges for the
command in question and try
again.
received from the keyboard,
usually caused by a
communication error. Verify that
the keyboard-to-system cable is
securely connected.
The control sequence sent from the
keyboard was incomplete, usually
indicating a communication error.
Verify that the keyboard-to-system
cable is not producing an
intermittent connection.
The * key has been pressed, but
there is no definition for this
button.

Hide quick links:

Advertisement

Table of Contents
loading