PT STATUS: Status report for point specified.
PT TESTED: This point walk tested.
PREV STATE: Event modifier for arming and disarming events. Shows the previous
arming state of the area. The number before PREV STATE in the command center
display defines the previous state as follows:
1 = Area previously master armed.
2 = Area previously perimeter instant armed.
3 = Area previously perimeter delay armed.
4 = Area previously disarmed.
PWR RESET: Power was reset at specified time.
RAM FAIL: RAM programming session terminated abnormally or RAM using
incorrect passcode and/or lock code.
RAM OK RAM: programming session terminated normally.
REBOOT: Panel reset.
RELAY SET: Relay set (activated). An event modifier showing how the relay
was set follows this event in the log.
RELY RESET: Relay reset (deactivated). An event modifier showing how the
relay was reset follows this event in the log.
REMO: Event modifier for BYPASS, RELAY SET, and RELY RESET events.
Indicates function initiated from RAM (Remote Account Manager).
REMO RESET: Panel reset from RAM (Remote Account Manager).
RESTORAL: Restoral at device in area specified.
SDI FAIL: SDI device specified is not working. 1 - 8 supervised command
centers, 017, 018, 019 = printers.
SDI RSTOR: The problem with SDI device specified resolved.
SENSOR: Event modifier for SENS RESET event. Shows the relay number
activated for reset.
SENS RESET: User reset area sensor in area specified. An event modifier
showing the relay number activated for reset follows this event.
SKD CHG: User changed time for Sked specified to be executed.
SKD XEQ: Sked executed.
SKED: Event modifier for BYPASS, RELAY SET, and RELY RESET events. Indicates
function initiated by a SKED (scheduled event).
STAT RPT: Status report sent.
TEST RPT: Test report sent.
TIME CHG: User changed panel's time.
TROUBLE: Trouble condition at point specified.
USER CMD 7: User initiated special alarm in the area specified.
USER CMD 9: User initiated special alarm in the area specified.
WALK END: Walk test in area specified completed.
WALK STRT: Walk test initiated in specified area.