Bosch IntuiKey Keyboard User Manual page 21

Table of Contents

Advertisement

IntuiKey Keyboard
Error
Name
Error 53
Switcher Empty
Error 55
SEQUENCE Priority
Error 56
SEQUENCE Request
Error 58
SEQUENCE Request
Error 60
PROGRAM Request
Error 62
PROGRAM Request
Error 63
PROGRAM Request
Error 70
Monitor No Allocated to Group
Error 71
Step Monitor Required
Error 78
Must Enter Alarm Number
Error 80
Trunk Not Available
Error 81
Satellite Trunk Seized
Error 89
Internal Stack Error
Error 90
Keyboard Entry Undefined
Error 92
Keyboard Entry Out of Range
Error 94
Keyboard Entry Invalid
Error 95
Keyboard Entry Incomplete
Error 96
* (STAR) Undefined
Error 128 No Communications
Bosch Security System, Inc.
Controlling Allegiant Series Video Switchers | en
Description
The user has attempted to control a sequence using the NEXT,
PREV, RUN, or HOLD keys, without there being a sequence loaded.
The switcher sequence being requested or cleared requires
monitors that are in use by a user of equal or higher priority.
Contact a user with higher priority or have the system administrator
clear the monitors in question.
The user has attempted to load a sequence that is being edited in
the PROGRAM mode. Once editing is complete, the sequence may
be loaded.
The sequence being requested is a relative sequence, and the user
is only permitted access to absolute sequences.
The user has attempted to program a sequence that is currently
running. The sequence must first be stopped before any editing can
be performed.
The user has attempted to program a new sequence when the
sequence memory space has been depleted. Delete unused
sequences, then program the new sequence.
Another user is already programming a sequence on this monitor.
This monitor cannot be used for alarm operations; it has not been
designated as alarm-capable by the system programmer.
A group of alarm monitors may not have an armed Review (display)
monitor without having armed Step (sequence) monitors.
A specific alarm number must be entered when arming or disarming
an alarm.
An attempt was made to access a remote camera connected to a
satellite system, but no unused trunk lines are currently available.
The camera currently viewed has changed because an operator with
a higher priority has selected a different camera that seized the
trunk line from the satellite.
A stack overflow within the system has occurred. Report this to the
manufacturer.
The keyboard entry is not defined. Check the appropriate section of
the instruction manual for the desired operation and try again.
The data entered for a valid command was not in the permissible
range. Check the appropriate section of the instruction manual for
acceptable ranges for the command in question and try again.
An invalid character was received from the keyboard. Usually this
indicates a communications error. Verify that the keyboard-to-
system cable is not producing an intermittent connection.
The control sequence sent from the keyboard was incomplete.
Usually this indicates a communications error. Verify that the
keyboard-to-system cable is not producing an intermittent
connection.
The * key has been pressed, but there is no definition for this
button.
The keyboard cannot communicate with the Allegiant.