MOTU UltraLite- mk3 Hybrid User Manual page 96

For windows
Hide thumbs Also See for UltraLite- mk3 Hybrid:
Table of Contents

Advertisement

In Min/Max mode, Min and Max let you scale the
grid by moving the -1.0 and +1.0 points along the
axis. Min/Max mode lets you control the graph
boundaries directly.
Persistence
The Persistence controls (Figure 10-44) affect the
appearance of data from when it is first displayed
until it disappears from the grid.
Figure 10-44: The Persistence controls.
Length
Length (Figure 10-44) sets the number of recent
samples to show on the plot. For example, when
Length is set to 10,000, the 10,000 most recent
samples are shown.
Decay
The brightness (in Grayscale mode) or hue (in
Color mode) of each sample on the plot is
determined by a linear scale, with the most recent
sample displayed at the maximum value and the
oldest sample displayed at the minimum value.
Decay (Figure 10-44 on page 96) determines the
brightness or hue of the minimum value. When
Decay is zero, the oldest sample is black. When
Decay is +1.000, the oldest sample is fully opaque
(in Grayscale mode) or red (in Color mode).
Warp
Warp (Figure 10-44) determines the position of
data points after they are first drawn. When warp is
zero, data points remain in the same position.
When warp is positive, they contract towards the
origin (center of the grid). When warp is negative,
they expand away from the origin. The further the
warp value is from zero, the greater the effect.
96
Using the X-Y Plot
The X-Y Plot helps you "see" the width of the stereo
field of a mix. It also helps you determine if a mix
has issues with polarity, as follows:
Activity on the X-Y Plot
Signal activity occurs mostly
along the x = y axis (lower left
to upper right) and the Corre-
lation meter reading is high
Signal activity occurs mostly
along the y = -x axis (upper left
to lower right) and the Correla-
tion meter reading is low (near
-1)
Signal activity occurs in a
seemingly random fashion
throughout the grid
If a stereo signal is out of phase, it is not mono
compatible because it can cancel itself out, either
partially or nearly completely, when collapsed to
mono.
In polarity
Out of polarity
Figure 10-45: Checking polarity in a stereo signal with the X-Y Plot.
What it indicates
Left and right channels are pre-
dominantly in polarity (the ste-
reo field is relatively narrow)
Left and right channels are pre-
dominantly out of polarity (not
in phase)
No phase relationship exists
(i.e. it is probably a wide stereo
field)
No polarity
C U E M I X F X

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ultralite-mk3 hybrid

Table of Contents