many registers closed. Check your
system to ensure that there are no airflow
problems.
If you continue to experience short
battery life after fixing airflow problems,
your furnace has a limit switch that
functions even when airflow is adequate.
In this case, a 24 V single-pole , normally-
open (SPNO) relay must be added to the
system using the following procedure.
CAUTION
A qualified service person
should perform this installation.
30
1. Disconnect 120v AC power from the
system.
2. Obtain a 24v SPNO relay (No. 8A04-
1).
3. Connect the limit switch to the
contact side of the relay (see fig. 7,
part B ).
4. Reconnect power to the system. Test
the system and thermostat (see
TESTING YOUR THERMOSTAT).