Diagnostic Error Code
071-04X-XXX Audio port failure
071-195-XXX Audio port Test aborted by user
071-196-XXX Audio port test halt, error threshold exceeded
071-197-XXX Audio port test warning
071-198-XXX Audio port test aborted
071-199-XXX Audio port test failed, cause unknown
071-25X-XXX Audio port failure
080-000-XXX Game Port interface Test Passed
080-XXX-XXX Game Port interface Error
080-195-XXX Game Port interface Test aborted by user
080-196-XXX Game Port interface test halt, error threshold
exceeded
080-197-XXX Game Port interface test warning
080-198-XXX Game Port interface test aborted
68
Lenovo S310 All-In-OneHardware Maintenance Manual
FRU/Action
1. Run the Setup Utility program.
2. Audio card, if installed.
3. System board
Information only Restart the test, if necessary.
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility program" on page 51.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility program" on page 51.
2. Flash the system and re-test. See "Flash update
procedures" on page 127.
3. Go to "Undetermined problems" on page 76.
1. See "Undetermined problems" on page 76.
2. Flash the system and re-test. See "Flash update
procedures" on page 127.
3. Replace component under function test.
1. Speakers
2. Audio card, if installed
3. System board
No action
1. Remove the game port device and re-test the
system.
Information only Restart the test, if necessary.
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility program" on page 51.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility program" on page 51
2. Flash the system and re-test. See "Flash update
procedures" on page 127.
3. Go to "Undetermined problems" on page 76.