Diagnostic Error Code
020-197-XXX PCI test warning
020-198-XXX PCI test aborted
020-199-XXX PCI test failed, cause unknown
020-262-XXXPCI system error
025-000-XXXIDE interface Test Passed
025-00X-XXX 025-01X-XXX IDE interface failure
025-027-XXX IDE interface Configuration/Setup error
025-02X-XXX 025-03X-XXX 025-04X-XXX IDE Interface
failure
025-195-XXX IDE interface Test aborted by user
025-196-XXX IDE interface test halt, error threshold
exceeded
FRU/Action
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility program" on page 51.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility program" on page 51.
2. Flash the system and re-test. See "Flash update
procedures" on page 127.
3. Go to "Undetermined problems" on page 76.
1. Go to "Undetermined problems" on page 76.
2. Flash the system and re-test. See "Flash update
procedures" on page 127.
3. Replace component under function test.
1. PCI card
2. Riser card, if installed.
3. System board
No action
1. IDE signal cable
2. Check power supply voltages.
3. Reseat IDE signal cable.
4. IDE device
5. System board
1. IDE signal cable
2. Flash the system. See "Flash update procedures"
on page 127.
3. Reseat IDE signal cable.
4. IDE device
5. System board
1. IDE signal cable
2. Check power supply.
3. Reseat IDE signal cable.
4. IDE device
5. System board
Information only Restart the test, if necessary.
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
Chapter 7
.