Diagnostic Error Code
011-198-XXX Serial port test aborted
011-199-XXX Serial port test failed, cause unknown
011-2XX-XXX Serial port signal failure
014-000-XXX Parallel port Interface Test Passed
014-001-XXX Parallel port Presence
014-002-XXX 014-003-XXX Parallel port Timeout/Parity
error
014-013-XXX 014-014-XXX Parallel port Control
Signal/Loopback test failure
014-015-XXX Parallel port External Loopback failure
014-027-XXX Parallel port Configuration/Setup error
014-03X-XXX 014-04X-XXX Parallel port failure
014-195-XXX Parallel port Test aborted by user
014-196-XXX Parallel port test halt, error threshold
exceeded
014-197-XXX Parallel port test warning
014-198-XXX Parallel port test aborted
62
Lenovo S310 All-In-OneHardware Maintenance Manual
FRU/Action
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility program" on page 51.
2. Flash the system and re-test. See "Flash update
procedures" on page 127.
3. Go to "Undetermined problems" on page 76.
1. Go to "Undetermined problems" on page 76.
2. Flash the system and re-test. See "Flash update
procedures" on page 127.
3. Replace component under function test.
1. External serial device
2. System board
No action
1. Remove external parallel device, if present.
2. Run the Setup Utility program, enable port
3. System board
System board
System board
1. Wrap plug
2. System board
1. Run the Setup Utility program, enable port
2. Flash the system. See "Flash update procedures"
on page 127.
3. System board
System board
Information only Restart the test, if necessary.
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility program" on page 51.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
1. If a component is called out, make sure it is
connected and/or enabled.
2. Flash the system and re-test. See "Flash update
procedures" on page 127.
3. Go to "Undetermined problems" on page 76.