Figure 11-11.
Installing the Heatsink
8. Place one heatsink clip in position, so the tab on the clip engages the slot on the heatsink (A in Figure
11-12). Position the clip so that the plastic tab on the retaining bracket is located in the narrow portion
of the heatsink clip opening.
9. Press one end of the clip down until it locks into position in the retainer. (B in Figure 11-12). Ensure that
the plastic tab on the RM bracket protrudes through the corresponding opening in the heatsink clip.
Some sideways movement of the clip may be necessary to achieve proper installation.
10. Press the other end of the clip down into position on the retainer (C in Figure 11-12). Ensure that the
plastic tab on the RM bracket protrudes through the corresponding opening in the heatsink clip.
100